Overview
The Quantenna Wi-Fi chipset has been identified as having a critical vulnerability that can potentially lead to system compromise or data leakage. This vulnerability impacts all users of the Quantenna Wi-Fi chipset through version 8.0.0.28 of the latest SDK. It is a critical issue as it allows for command injection, enabling malicious actors to potentially gain control over affected systems.
Vulnerability Summary
CVE ID: CVE-2025-3459
Severity: High – CVSS 7.7
Attack Vector: Local
Privileges Required: None
User Interaction: None
Impact: System compromise or data leakage
Affected Products
Share secrets securely
Ameeba is private infrastructure for communication and sensitive work built on encrypted identity instead of exposed corporate identity systems.
Passwords, credentials, confidential files, screenshots, internal discussions, sensitive AI context, and private coordination should not become exposed across ordinary communication platforms.
- • Encrypted identity
- • Private Spaces for organizations and teams
- • End-to-end encrypted chat, calls, files, and notes
- • Sensitive AI work and protected collaboration
- • Built for information that cannot leak
Our mission is to secure human work alongside AI.
Product | Affected Versions
Quantenna Wi-Fi chipset | Up to version 8.0.0.28
How the Exploit Works
The exploit takes advantage of a local control script known as transmit_file. This script is vulnerable to command injection, which allows a potential attacker to inject malicious commands that can be executed by the system. This is due to improper neutralization of argument delimiters in a command, also known as ‘Argument Injection’ (CWE-88).
Conceptual Example Code
Below is a conceptual example of how this vulnerability might be exploited using a shell command:
$ ./transmit_file --host=127.0.0.1 --port=80 --payload='; rm -rf /'
In this conceptual example, the injected command (`; rm -rf /`) would delete all files in the system if executed. Please note that this is a conceptual example and the actual exploitation might be different based on the system configuration and the attacker’s intent.
Mitigation Guidance
As of the time of this report, the vendor has not released a patch for this vulnerability. Until one is available, a Web Application Firewall (WAF) or Intrusion Detection System (IDS) can be used as temporary mitigation. Additionally, the vendor has released a best practices guide that should be followed to minimize the risk of this vulnerability.