Author: Ameeba

  • CVE-2025-32872: SQL Injection Vulnerability in TeleControl Server Basic

    Overview

    In the ever-evolving landscape of cyber threats, a new vulnerability has been identified, CVE-2025-32872, that poses a significant risk to systems running TeleControl Server Basic. This vulnerability exposes these systems to SQL injection attacks, potentially leading to unauthorized access or control over the system. This issue arises from the internally used ‘GetOverview’ method, and its exploitation could provide an authenticated remote attacker with the capability to bypass authorization controls. The severity of this vulnerability is further emphasized by its potential to enable malicious actors to alter the application’s database and execute code with “NT AUTHORITYNetworkService” permissions.

    Vulnerability Summary

    CVE ID: CVE-2025-32872
    Severity: High (8.8)
    Attack Vector: Network
    Privileges Required: Low (Authenticated User)
    User Interaction: None
    Impact: System compromise, data leakage, unauthorized access and control

    Affected Products

    Product | Affected Versions

    TeleControl Server Basic | All versions < V3.1.2.2 How the Exploit Works

    This vulnerability stems from the ‘GetOverview’ method used internally by the TeleControl Server Basic. An authenticated remote attacker can exploit this method, sending specially crafted SQL queries that the system will execute. These queries can be designed to bypass the authorization controls of the application, granting the attacker unrestricted access to the database. This vulnerability also allows the attacker to execute code with “NT AUTHORITYNetworkService” permissions, potentially leading to a full system compromise.

    Conceptual Example Code

    The below example demonstrates the potential structure of a malicious SQL query that might be used to exploit this vulnerability.

    POST /GetOverview HTTP/1.1
    Host: target.example.com
    Content-Type: application/json
    {
    "sql_query": "'; DROP TABLE users; --"
    }

    This conceptual example illustrates a basic SQL injection attack, where the attacker appends a malicious query (`DROP TABLE users;`) to the existing query. When this request is processed, the ‘GetOverview’ method may execute the appended query, potentially leading to destructive consequences such as deletion of critical data.

    Mitigation and Prevention

    The most effective mitigation strategy for this vulnerability is to apply the vendor patch, upgrading the TeleControl Server Basic to version V3.1.2.2 or later. In the absence of a vendor patch or for immediate, temporary mitigation, deploying Web Application Firewalls (WAFs) or Intrusion Detection Systems (IDS) can help identify and block potential SQL injection attacks. Regular security audits and secure coding practices can also help in preventing such vulnerabilities.

  • CVE-2025-45429: Stack Overflow Vulnerability in Tenda ac9 v1.0 Router

    Overview

    CVE-2025-45429 is a severe and potentially damaging vulnerability found in the Tenda ac9 v1.0 router, specifically in the firmware version V15.03.05.14_multi. This particular vulnerability exposes a stack overflow situation in /goform/WifiWpsStart, which could potentially lead to remote arbitrary code execution by malicious actors.
    This vulnerability is notable as the Tenda ac9 v1.0 router is a widely-used piece of hardware in both personal and professional environments. The consequences of a successful exploit could be severe, ranging from system compromise to data leakage, which could have a significant impact on both individuals and businesses alike.

    Vulnerability Summary

    CVE ID: CVE-2025-45429
    Severity: Critical (9.8 CVSS Severity Score)
    Attack Vector: Network
    Privileges Required: None
    User Interaction: None
    Impact: System compromise and potential data leakage.

    Affected Products

    Product | Affected Versions

    Tenda ac9 v1.0 router | Firmware V15.03.05.14_multi

    How the Exploit Works

    The exploit takes advantage of a stack overflow vulnerability in the /goform/WifiWpsStart endpoint of the router’s firmware. A malicious actor could potentially send a specially crafted request to this endpoint, overflowing the stack and allowing them to execute arbitrary code remotely. This could lead to a complete system compromise, giving the attacker unrestricted access to the system and potentially leading to data leakage.

    Conceptual Example Code

    The following is a conceptual example of how the vulnerability might be exploited. This is a sample HTTP request that could be used to overflow the stack and execute arbitrary code:

    POST /goform/WifiWpsStart HTTP/1.1
    Host: target_router_ip
    Content-Type: application/json
    { "malicious_payload": "A"*1024 }  // Stack overflow with 1024 'A' characters

    Please note that this is only a conceptual example and actual payloads may vary. Nonetheless, the result of such an attack could be significant, leading to a system compromise or potential data leakage. It is therefore highly recommended that users of the affected product apply the vendor patch immediately or use a Web Application Firewall (WAF) or Intrusion Detection System (IDS) as temporary mitigation.

  • CVE-2025-45428: Remote Arbitrary Code Execution Vulnerability in Tenda AC9 v1.0 Firmware

    Overview

    The Common Vulnerabilities and Exposures (CVE) system has recently identified a critical vulnerability, CVE-2025-45428, found in Tenda AC9 v1.0 with firmware V15.03.05.14_multi. This vulnerability could potentially allow a remote attacker to execute arbitrary code on the affected system, leading to a full-scale compromise of the system and potential data leakage. As Tenda AC9 routers are widely used, this vulnerability could pose a significant risk to countless networks and systems worldwide, making the understanding and mitigation of this vulnerability crucial for maintaining cybersecurity standards.

    Vulnerability Summary

    CVE ID: CVE-2025-45428
    Severity: Critical (CVSS score 9.8)
    Attack Vector: Network
    Privileges Required: None
    User Interaction: None
    Impact: System compromise and potential data leakage

    Affected Products

    Product | Affected Versions

    Tenda AC9 v1.0 | Firmware V15.03.05.14_multi

    How the Exploit Works

    The exploit takes advantage of a stack overflow vulnerability in the rebootTime parameter of the /goform/SetSysAutoRebbotCfg endpoint in the Tenda AC9 firmware. A remote attacker can send a specially crafted request to this endpoint, causing the stack overflow, which in turn allows the execution of arbitrary code. The attacker does not need any special privileges to exploit this vulnerability, and no user interaction is required, which makes this vulnerability particularly dangerous.

    Conceptual Example Code

    Here is a conceptual example of how a malicious HTTP request exploiting this vulnerability might look:

    POST /goform/SetSysAutoRebbotCfg HTTP/1.1
    Host: target.example.com
    Content-Type: application/json
    { "rebootTime": "[malicious_payload]" }

    In the above example, “[malicious_payload] represents a string of code designed to cause a stack overflow and execute arbitrary code on the system.

    Recommended Mitigation

    Users of the affected Tenda AC9 firmware are strongly advised to apply the vendor patch as soon as it becomes available. In the meantime, utilizing a Web Application Firewall (WAF) or Intrusion Detection System (IDS) can serve as a temporary mitigation for this vulnerability. Regularly updating systems and software, and monitoring network traffic for any suspicious activity are general best practices that can also help protect against such vulnerabilities.

  • CVE-2025-45427: Critical Stack Overflow Vulnerability in Tenda AC9 v1.0 Firmware

    Overview

    The cybersecurity community has identified a critical vulnerability in the firmware version V15.03.05.14_multi of Tenda AC9 v1.0. Known as CVE-2025-45427, this vulnerability can lead to remote arbitrary code execution due to a stack overflow error in the security parameter of /goform/WifiBasicSet. As a cybersecurity expert, it’s important to understand the nature of this vulnerability, its implications, and the mitigation measures that can be implemented to safeguard against potential exploits. This vulnerability poses a serious threat to users due to its potential for system compromise and data leakage.

    Vulnerability Summary

    CVE ID: CVE-2025-45427
    Severity: Critical (9.8)
    Attack Vector: Network
    Privileges Required: None
    User Interaction: None
    Impact: Potential system compromise and data leakage

    Affected Products

    Product | Affected Versions

    Tenda AC9 v1.0 | V15.03.05.14_multi

    How the Exploit Works

    The vulnerability CVE-2025-45427 exploits a flaw in the security parameter of /goform/WifiBasicSet. When a particular input size is exceeded, this leads to a stack overflow error. As the stack overflow error occurs, it creates an opportunity for an attacker to execute arbitrary code remotely. This can potentially lead to full system compromise or data leakage.

    Conceptual Example Code

    Below is a conceptual example of how the vulnerability might be exploited, demonstrated through an HTTP request:

    POST /goform/WifiBasicSet HTTP/1.1
    Host: target_router_ip
    Content-Type: application/json
    {
    "security_param": "A"*10000
    }

    In the above example, a JSON payload is sent to the vulnerable endpoint with a `security_param` parameter containing a large number of ‘A’ characters. This is enough to cause a stack overflow, allowing the attacker to eventually execute arbitrary code remotely.

    Mitigation Measures

    The recommended mitigation measure for this vulnerability is to apply the vendor patch if it’s available. In scenarios where the vendor patch is not available or cannot be applied immediately, using a Web Application Firewall (WAF) or an Intrusion Detection System (IDS) can serve as temporary mitigation. These systems can help monitor network traffic and detect potential exploits of this vulnerability, thereby providing an additional layer of security.
    In conclusion, CVE-2025-45427 is a critical vulnerability that demands immediate attention and action. The potential for system compromise and data leakage makes it a significant threat to any system running the affected firmware version of Tenda AC9 v1.0. By understanding the nature of this vulnerability and applying the recommended mitigation measures, it is possible to significantly reduce the risk of exploitation.

  • CVE-2025-32871: SQL Injection Vulnerability in TeleControl Server Basic

    Overview

    In the rapidly evolving world of cybersecurity, new threats and vulnerabilities are constantly emerging. One such vulnerability, CVE-2025-32871, affects TeleControl Server Basic, a widely-used software application. This vulnerability has been identified in versions of the application prior to V3.1.2.2.
    The vulnerability exposes the application to SQL injection attacks which, if successfully exploited, could allow an authenticated remote attacker to bypass authorization controls. This means they could read from and write to the application’s database and execute code with “NT AUTHORITYNetworkService” permissions. Given the potential for system compromise or data leakage, this vulnerability presents a serious risk to organizations using the affected software.

    Vulnerability Summary

    CVE ID: CVE-2025-32871
    Severity: High (8.8 CVSS Score)
    Attack Vector: Network
    Privileges Required: Low
    User Interaction: None
    Impact: Potential system compromise and data leakage

    Affected Products

    Product | Affected Versions

    TeleControl Server Basic | All versions < V3.1.2.2 How the Exploit Works

    This exploit works by exploiting the ‘MigrateDatabase’ method that is used internally by the TeleControl Server Basic. An attacker can inject SQL commands into the data input fields of this method. Since the application does not properly sanitize the inputs, these malicious commands can be executed directly on the application’s database.
    This, in turn, allows the attacker to bypass authorization controls, enabling them to read from and write to the application’s database and execute code with “NT AUTHORITYNetworkService” permissions. The attacker can gain control over the system and potentially access sensitive data.

    Conceptual Example Code

    An attacker with authenticated access could potentially exploit the vulnerability by sending a malicious request similar to:

    POST /MigrateDatabase HTTP/1.1
    Host: target.example.com
    Content-Type: application/sql
    { "database_command": "DROP TABLE users;" }

    In this conceptual example, the “DROP TABLE users;” command would delete the ‘users’ table from the database, potentially causing significant data loss and disruption.
    Finally, it is recommended to apply the vendor patch as soon as possible or use a Web Application Firewall (WAF) or Intrusion Detection System (IDS) as a temporary mitigation. Regularly updating and patching software applications is crucial in minimizing the risk of such vulnerabilities.

  • CVE-2025-32870: SQL Injection Vulnerability in TeleControl Server Basic

    Overview

    TeleControl Server Basic, a widely used industrial control system (ICS) software, has a critical vulnerability that threatens the integrity of systems running any version prior to V3.1.2.2. CVE-2025-32870, with a significant CVSS score of 8.8, reveals a concerning weakness in the ‘GetTraces’ method, which is prone to SQL injection attacks. This vulnerability is particularly notable due to its potential to enable an authenticated remote attacker to bypass authorization controls, execute malicious scripts, and potentially lead to a system compromise or data leak.

    Vulnerability Summary

    CVE ID: CVE-2025-32870
    Severity: High (8.8 CVSS score)
    Attack Vector: Network
    Privileges Required: Low
    User Interaction: Required
    Impact: Bypassing of Authorization Controls, Data leakage, System Compromise

    Affected Products

    Product | Affected Versions

    TeleControl Server Basic | All versions < V3.1.2.2 How the Exploit Works

    The exploit takes advantage of a SQL Injection vulnerability in the ‘GetTraces’ method of the TeleControl Server Basic application. An attacker who has authenticated access to the system can send a specially crafted SQL query to the application via port 8000. This can allow the attacker to manipulate the database by reading from it, writing to it, or even executing code with “NT AUTHORITYNetworkService” permissions.

    Conceptual Example Code

    Here’s a conceptual example of what a malicious SQL injection might look like:

    POST /GetTraces HTTP/1.1
    Host: target.example.com:8000
    Content-Type: application/sql
    { "query": "SELECT * FROM Users; DROP TABLE Users;" }

    In this example, the ‘DROP TABLE Users;’ command would delete the entire ‘Users’ table from the database if successfully executed, demonstrating the potential severity of this vulnerability.

    Mitigation

    Users of TeleControl Server Basic are strongly advised to update to the latest version (V3.1.2.2 or later) as soon as possible. If an immediate update is not feasible, a temporary mitigation measure involves the use of a Web Application Firewall (WAF) or Intrusion Detection System (IDS) to monitor and filter out potentially harmful SQL queries.

  • CVE-2025-32869: SQL Injection Vulnerability in TeleControl Server Basic

    Overview

    A critical vulnerability, CVE-2025-32869, has been found in all versions of TeleControl Server Basic prior to V3.1.2.2. This vulnerability relates to SQL injection, one of the most severe web application security risks and allows for significant system compromise by an attacker. It exposes systems to potential unauthorized database manipulation and code execution, which can subsequently lead to data leakage or a complete system takeover.
    The vulnerability affects organizations that rely on TeleControl Server Basic for remote control systems. Given the severity and the potential impact, it is crucial for organizations to understand and mitigate this vulnerability as soon as possible.

    Vulnerability Summary

    CVE ID: CVE-2025-32869
    Severity: High, CVSS Score 8.8
    Attack Vector: Network
    Privileges Required: Low (Authenticated Access)
    User Interaction: None
    Impact: System compromise, Data leakage

    Affected Products

    Product | Affected Versions

    TeleControl Server Basic | All versions < V3.1.2.2 How the Exploit Works

    The vulnerability resides in the ‘ImportCertificate’ method internally used by the TeleControl Server Basic application. An authenticated attacker can inject malicious SQL queries via this method. This SQL injection can bypass authorization controls, enabling the attacker to read and write to the application’s database, and execute code with “NT AUTHORITYNetworkService” permissions. Successful exploitation requires the attacker to have access to port 8000 on a system where a vulnerable version of the application is running.

    Conceptual Example Code

    Below is a conceptual example of how the vulnerability might be exploited. This example is not meant to be a working exploit, but a demonstration of the attack concept.

    POST /ImportCertificate HTTP/1.1
    Host: target.example.com:8000
    Content-Type: application/json
    Authorization: Bearer [UserAuthToken]
    { "certificate": "'; DROP TABLE Users;--" }

    In this example, the attacker sends a POST request to the vulnerable endpoint `/ImportCertificate`. The malicious payload in the `certificate` parameter is an SQL command designed to delete the `Users` table from the database. If the application does not properly sanitize this input, the command will be executed, leading to potential data loss or unauthorized data access.

    Mitigations

    The ideal solution is to apply the vendor-provided patch that fixes this vulnerability. Users of TeleControl Server Basic should upgrade their software to version V3.1.2.2 or later as soon as possible.
    In cases where immediate patching is not possible, implementing a Web Application Firewall (WAF) or Intrusion Detection System (IDS) that can detect and block SQL Injection attempts can serve as a temporary mitigation. However, these measures are not foolproof and should be used in conjunction with other security controls, like regular software updates and strong authentication mechanisms.

  • CVE-2025-32868: SQL Injection Vulnerability in TeleControl Server Basic

    Overview

    CVE-2025-32868 is a security vulnerability that has been identified in all versions of TeleControl Server Basic prior to V3.1.2.2. This vulnerability exposes systems to SQL injection attacks, allowing authenticated remote attackers to bypass authorization controls, read from and write to the application’s database, and execute code with “NT AUTHORITY\NetworkService” permissions. This vulnerability is particularly dangerous due to its potential to compromise entire systems and cause data leakage.

    Vulnerability Summary

    CVE ID: CVE-2025-32868
    Severity: High (8.8)
    Attack Vector: Network
    Privileges Required: Low
    User Interaction: None
    Impact: System compromise, data leakage

    Affected Products

    Product | Affected Versions

    TeleControl Server Basic | All versions < V3.1.2.2 How the Exploit Works

    The vulnerability resides in the ‘ExportCertificate’ method used internally by the application. An attacker can exploit this vulnerability by sending a specially crafted SQL query to the server. The application fails to properly sanitize the SQL query, allowing the attacker to manipulate the SQL statement. The manipulated SQL statement could potentially execute arbitrary SQL code, bypassing authorization controls, and gaining access to the application’s database.

    Conceptual Example Code

    Consider this hypothetical scenario where an attacker sends a malicious SQL statement to the server. The server fails to sanitize the input, causing the SQL statement to be executed. Here’s what such a request might look like:

    POST /ExportCertificate HTTP/1.1
    Host: target.example.com
    Content-Type: application/json
    { "certificate_id": "1; DROP TABLE users;" }

    In the sample above, the attacker is injecting a `DROP TABLE users;` command after the legitimate query. If the server processes this request, it could potentially lead to the deletion of the `users` table in the database.
    Please note that this is a simplified example for illustrative purposes. In a real-world scenario, an attacker would likely use more complex and less detectable SQL injection techniques.

    Mitigation

    All users of TeleControl Server Basic are strongly encouraged to update to version V3.1.2.2 or later as soon as possible, as these versions contain a patch for this vulnerability. In the meantime, users can use a Web Application Firewall (WAF) or Intrusion Detection System (IDS) as a temporary mitigation measure. These tools can help detect and block SQL injection attacks.
    Remember that while these measures can reduce the risk, they are not a substitute for patching the application and keeping it up to date. Regularly applying patches and updates is one of the most effective ways to protect your systems from known vulnerabilities.

  • CVE-2025-37087: High-Risk Vulnerability in HPE Performance Cluster Manager

    Overview

    In the world of cybersecurity, new vulnerabilities are constantly being uncovered and exploited. One such vulnerability, CVE-2025-37087, poses a significant threat to organizations using the HPE Performance Cluster Manager (HPCM). This flaw could allow a potential attacker to gain unauthorized access to any file on the server host, providing a gateway to potential system compromise, data leakage, or even worse, total control over the server.
    This vulnerability is of particular concern due to the severity of its potential impact. With a CVSS Severity Score of 9.8, it’s clear that this vulnerability could have disastrous consequences if left unpatched. The impacted systems are those running the cmdb service of HPE Performance Cluster Manager, making it paramount for organizations using this service to take immediate action.

    Vulnerability Summary

    CVE ID: CVE-2025-37087
    Severity: Critical (9.8 CVSS Score)
    Attack Vector: Network
    Privileges Required: None
    User Interaction: None
    Impact: Potential system compromise and data leakage

    Affected Products

    Product | Affected Versions

    HPE Performance Cluster Manager | All versions prior to patch

    How the Exploit Works

    The vulnerability lies in the cmdb service of the HPE Performance Cluster Manager. A flaw in this service could allow an attacker to manipulate the system into granting unauthorized access to arbitrary files on the server host. This could potentially allow the attacker to view sensitive information, modify system configurations, or even execute malicious code.

    Conceptual Example Code

    The following is a conceptual example of how this vulnerability might be exploited. Please note that this is only a theoretical example and does not reflect a real-world exploit scenario.

    GET /cmdb?file=../../../../etc/passwd HTTP/1.1
    Host: vulnerable-server.example.com

    In this example, the attacker is attempting to exploit the vulnerability by using a path traversal attack to access the /etc/passwd file, which may contain sensitive user information.

    Mitigation

    To mitigate the impact of this vulnerability, it’s crucial to apply the vendor-supplied patch immediately. If for some reason, the patch cannot be applied right away, a temporary solution could be to use a Web Application Firewall (WAF) or Intrusion Detection System (IDS) to monitor and block potential exploit attempts. However, these should only be considered temporary solutions, and applying the patch should be the highest priority.

  • CVE-2025-32867: Critical SQL Injection Vulnerability in TeleControl Server Basic

    Overview

    A substantial security vulnerability, with a severity score of 8.8, has been identified in all versions of TeleControl Server Basic preceding V3.1.2.2. This vulnerability impacts a broad range of industries and users that rely on TeleControl Server Basic for their daily operations. The flaw threatens the integrity, confidentiality, and availability of the affected systems, making it a significant cybersecurity concern that requires urgent attention.

    Vulnerability Summary

    CVE ID: CVE-2025-32867
    Severity: Critical (8.8)
    Attack Vector: Network
    Privileges Required: Low
    User Interaction: None
    Impact: System compromise, data leakage

    Affected Products

    Product | Affected Versions

    TeleControl Server Basic | All versions < V3.1.2.2 How the Exploit Works

    The vulnerability lies within the ‘CreateBackup’ method, a feature used internally by the TeleControl Server Basic. This method is susceptible to SQL injection, a common web application flaw.
    An attacker can craft a malicious SQL query that manipulates the application’s database, allowing the attacker to bypass authorization controls. The attacker can then read from and write to the database, and even execute code with “NT AUTHORITYNetworkService” permissions.
    This vulnerability is exploitable remotely, and only requires the attacker to have access to port 8000 on a system running a vulnerable version of TeleControl Server Basic.

    Conceptual Example Code

    Below is an example of how the SQL injection vulnerability might be exploited:

    POST /CreateBackup HTTP/1.1
    Host: target.example.com:8000
    Content-Type: application/json
    { "backupName": "'; DROP TABLE users; --" }

    In this hypothetical example, the attacker is attempting to delete the ‘users’ table from the database. The “;” character is used to end the current SQL command, and the “–” sequence is a SQL comment, effectively ignoring the remainder of the original query.

    Mitigation and Prevention

    As a temporary mitigation strategy, users can employ a Web Application Firewall (WAF) or Intrusion Detection System (IDS) to block or alert on suspicious activity. However, these measures do not resolve the underlying vulnerability.
    For a comprehensive solution, users should apply the latest patch provided by the vendor as soon as possible. This patch addresses the vulnerability by ensuring that all inputs are properly sanitized, thereby preventing SQL injection attacks.

Ameeba Chat
Private by Nature

Amorphous. Adaptive. Resilient.

Ameeba Chat