{"id":68124,"date":"2025-08-30T13:03:51","date_gmt":"2025-08-30T13:03:51","guid":{"rendered":""},"modified":"2025-09-16T11:36:42","modified_gmt":"2025-09-16T17:36:42","slug":"cve-2025-54482-critical-stack-based-buffer-overflow-vulnerability-in-the-biosig-project-libbiosig","status":"publish","type":"post","link":"https:\/\/www.ameeba.com\/blog\/cve-2025-54482-critical-stack-based-buffer-overflow-vulnerability-in-the-biosig-project-libbiosig\/","title":{"rendered":"<strong>CVE-2025-54482: Critical Stack-Based Buffer Overflow Vulnerability in The Biosig Project libbiosig<\/strong>"},"content":{"rendered":"<p><strong>Overview<\/strong><\/p>\n<p>A critical vulnerability has been discovered in the Biosig Project libbiosig software, specific to its MFER parsing functionality. This vulnerability, tagged as CVE-2025-54482, exposes systems to potential compromise and data leakage. By exploiting this flaw, an attacker can <a href=\"https:\/\/www.ameeba.com\/blog\/cve-2025-27577-arbitrary-code-execution-in-openharmony-via-race-condition-vulnerability\/\"  data-wpil-monitor-id=\"76239\">execute arbitrary code<\/a>, thereby gaining unauthorized access to sensitive data or control over the system. This <a href=\"https:\/\/www.ameeba.com\/blog\/cve-2025-8011-high-severity-heap-corruption-vulnerability-in-google-chrome-v8\/\"  data-wpil-monitor-id=\"75629\">vulnerability is particularly noteworthy due to its high severity<\/a> score, and the widespread use of the Biosig Project libbiosig in various sectors.<\/p>\n<p><strong>Vulnerability Summary<\/strong><\/p>\n<p>CVE ID: CVE-2025-54482<br \/>\nSeverity: Critical (CVSS: 9.8)<br \/>\nAttack Vector: Specially crafted MFER file<br \/>\nPrivileges Required: None<br \/>\nUser Interaction: Required (An attacker needs to provide a malicious <a href=\"https:\/\/www.ameeba.com\/blog\/cve-2025-54689-high-risk-php-remote-file-inclusion-vulnerability-in-urna\/\"  data-wpil-monitor-id=\"76613\">file to trigger this vulnerability<\/a>)<br \/>\nImpact: <a href=\"https:\/\/www.ameeba.com\/blog\/cve-2025-40741-stack-based-overflow-vulnerability-in-solid-edge-se2025-leading-to-potential-system-compromise\/\"  data-wpil-monitor-id=\"75736\">Potential system<\/a> compromise or data leakage<\/p>\n<p><strong>Affected Products<\/strong><\/p>\n<p>Product | Affected Versions<\/p>\n<p>The <a href=\"https:\/\/www.ameeba.com\/blog\/cve-2025-54480-critical-stack-based-buffer-overflow-vulnerability-in-the-biosig-project-libbiosig-3-9-0\/\"  data-wpil-monitor-id=\"83208\">Biosig Project libbiosig<\/a> | 3.9.0 and Master Branch (35a819fa)<\/p>\n<p><strong>How the Exploit Works<\/strong><\/p>\n<p>The <a href=\"https:\/\/www.ameeba.com\/blog\/cve-2025-32412-unchecked-buffer-vulnerability-in-fuji-electric-smart-editor\/\"  data-wpil-monitor-id=\"75708\">vulnerability manifests due to a stack-based buffer<\/a> overflow in the MFER parsing functionality of the Biosig Project libbiosig. If an attacker crafts a specific MFER file that exploits this flaw, they can <a href=\"https:\/\/www.ameeba.com\/blog\/cve-2025-50707-critical-remote-code-execution-vulnerability-in-thinkphp3-v-3-2-5\/\"  data-wpil-monitor-id=\"76570\">execute arbitrary code<\/a>. This happens on line 8751 of biosig.c on the current master branch (35a819fa), when the Tag is 4.<\/p>\n<p><strong>Conceptual Example Code<\/strong><\/p>\n<p>Here&#8217;s a simplified conceptual example of how the exploit might work:<\/p>\n<pre><code class=\"language-C\">\/\/ Attacker creates a malicious MFER file\nvoid maliciousMFERfile() {\nchar buf[4];\nFILE *hdr;\n\/\/ Set the Tag to 4\nint tag = 4;\n\/\/ Set the length greater than 4 to trigger the buffer overflow\nint len = 5;\nif (tag == 4) {\nif (len > 4) {\nfprintf(stderr, \"Warning MFER tag4 incorrect length %i>4\\n\", len);\ncurPos += ifread(buf, 1, len, hdr);\n}\n}\n}<\/code><\/pre>\n<p>This piece of code could generate a malicious MFER file that, when parsed by the vulnerable Biosig Project libbiosig functionality, would trigger the <a href=\"https:\/\/www.ameeba.com\/blog\/cve-2025-41388-stack-based-buffer-overflow-vulnerability-in-fuji-electric-smart-editor\/\"  data-wpil-monitor-id=\"75721\">buffer overflow<\/a> and lead to arbitrary code execution.<\/p>\n<p><strong>Mitigation Guidance<\/strong><\/p>\n<p>To mitigate this vulnerability, users are strongly advised to apply the vendor patch as soon as it is available. As a temporary measure, users can employ a Web Application Firewall (WAF) or Intrusion Detection System (IDS) to detect and <a href=\"https:\/\/www.ameeba.com\/blog\/cve-2025-8059-critical-privilege-escalation-vulnerability-in-b-blocks-wordpress-plugin\/\"  data-wpil-monitor-id=\"76323\">block attempts to exploit this vulnerability<\/a>. Regular monitoring of system logs, and isolation of affected <a href=\"https:\/\/www.ameeba.com\/blog\/cve-2025-30404-integer-overflow-vulnerability-in-executorch-resulting-in-potential-system-compromise\/\"  data-wpil-monitor-id=\"75948\">systems can also help in limiting the potential<\/a> damage.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Overview A critical vulnerability has been discovered in the Biosig Project libbiosig software, specific to its MFER parsing functionality. This vulnerability, tagged as CVE-2025-54482, exposes systems to potential compromise and data leakage. By exploiting this flaw, an attacker can execute arbitrary code, thereby gaining unauthorized access to sensitive data or control over the system. This [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false,"footnotes":""},"categories":[1],"tags":[],"vendor":[],"product":[],"attack_vector":[86,80],"asset_type":[],"severity":[],"exploit_status":[],"class_list":["post-68124","post","type-post","status-publish","format-standard","hentry","category-uncategorized","attack_vector-buffer-overflow","attack_vector-rce"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.4 - aioseo.com -->\n\t<meta name=\"description\" content=\"Overview A critical vulnerability has been discovered in the Biosig Project libbiosig software, specific to its MFER parsing functionality. This vulnerability, tagged as CVE-2025-54482, exposes systems to potential compromise and data leakage. By exploiting this flaw, an attacker can execute arbitrary code, thereby gaining unauthorized access to sensitive data or control over the system. This\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Ameeba\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/www.ameeba.com\/blog\/cve-2025-54482-critical-stack-based-buffer-overflow-vulnerability-in-the-biosig-project-libbiosig\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.4\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Ameeba Blog - Your Guide to a Safer Digital World.\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"CVE-2025-54482: Critical Stack-Based Buffer Overflow Vulnerability in The Biosig Project libbiosig - Ameeba Blog\" \/>\n\t\t<meta property=\"og:description\" content=\"Overview A critical vulnerability has been discovered in the Biosig Project libbiosig software, specific to its MFER parsing functionality. This vulnerability, tagged as CVE-2025-54482, exposes systems to potential compromise and data leakage. By exploiting this flaw, an attacker can execute arbitrary code, thereby gaining unauthorized access to sensitive data or control over the system. This\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/www.ameeba.com\/blog\/cve-2025-54482-critical-stack-based-buffer-overflow-vulnerability-in-the-biosig-project-libbiosig\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/www.ameeba.com\/blog\/wp-content\/uploads\/2025\/02\/image-5.png\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/www.ameeba.com\/blog\/wp-content\/uploads\/2025\/02\/image-5.png\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2025-08-30T13:03:51+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2025-09-16T17:36:42+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"CVE-2025-54482: Critical Stack-Based Buffer Overflow Vulnerability in The Biosig Project libbiosig - Ameeba Blog\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Overview A critical vulnerability has been discovered in the Biosig Project libbiosig software, specific to its MFER parsing functionality. This vulnerability, tagged as CVE-2025-54482, exposes systems to potential compromise and data leakage. By exploiting this flaw, an attacker can execute arbitrary code, thereby gaining unauthorized access to sensitive data or control over the system. This\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/www.ameeba.com\/blog\/wp-content\/uploads\/2025\/02\/image-5.png\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/cve-2025-54482-critical-stack-based-buffer-overflow-vulnerability-in-the-biosig-project-libbiosig\\\/#blogposting\",\"name\":\"CVE-2025-54482: Critical Stack-Based Buffer Overflow Vulnerability in The Biosig Project libbiosig - Ameeba Blog\",\"headline\":\"CVE-2025-54482: Critical Stack-Based Buffer Overflow Vulnerability in The Biosig Project libbiosig\",\"author\":{\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/author\\\/admin\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/wp-content\\\/uploads\\\/2025\\\/02\\\/image-5.png\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/#articleImage\"},\"datePublished\":\"2025-08-30T13:03:51+00:00\",\"dateModified\":\"2025-09-16T11:36:42+00:00\",\"inLanguage\":\"en-US\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/cve-2025-54482-critical-stack-based-buffer-overflow-vulnerability-in-the-biosig-project-libbiosig\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/cve-2025-54482-critical-stack-based-buffer-overflow-vulnerability-in-the-biosig-project-libbiosig\\\/#webpage\"},\"articleSection\":\"Uncategorized, Buffer Overflow, Rce\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/cve-2025-54482-critical-stack-based-buffer-overflow-vulnerability-in-the-biosig-project-libbiosig\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/category\\\/uncategorized\\\/#listItem\",\"name\":\"Uncategorized\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/category\\\/uncategorized\\\/#listItem\",\"position\":2,\"name\":\"Uncategorized\",\"item\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/category\\\/uncategorized\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/cve-2025-54482-critical-stack-based-buffer-overflow-vulnerability-in-the-biosig-project-libbiosig\\\/#listItem\",\"name\":\"CVE-2025-54482: Critical Stack-Based Buffer Overflow Vulnerability in The Biosig Project libbiosig\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/cve-2025-54482-critical-stack-based-buffer-overflow-vulnerability-in-the-biosig-project-libbiosig\\\/#listItem\",\"position\":3,\"name\":\"CVE-2025-54482: Critical Stack-Based Buffer Overflow Vulnerability in The Biosig Project libbiosig\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/category\\\/uncategorized\\\/#listItem\",\"name\":\"Uncategorized\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/#organization\",\"name\":\"Ameeba Blog\",\"description\":\"Your Guide to a Safer Digital World.\",\"url\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/wp-content\\\/uploads\\\/2025\\\/02\\\/image-5.png\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/cve-2025-54482-critical-stack-based-buffer-overflow-vulnerability-in-the-biosig-project-libbiosig\\\/#organizationLogo\"},\"image\":{\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/cve-2025-54482-critical-stack-based-buffer-overflow-vulnerability-in-the-biosig-project-libbiosig\\\/#organizationLogo\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/author\\\/admin\\\/#author\",\"url\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/author\\\/admin\\\/\",\"name\":\"Ameeba\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/cve-2025-54482-critical-stack-based-buffer-overflow-vulnerability-in-the-biosig-project-libbiosig\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ead225eeac23a6207666b4137a84523c6b550501a7ee49c81559ebd727825560?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"Ameeba\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/cve-2025-54482-critical-stack-based-buffer-overflow-vulnerability-in-the-biosig-project-libbiosig\\\/#webpage\",\"url\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/cve-2025-54482-critical-stack-based-buffer-overflow-vulnerability-in-the-biosig-project-libbiosig\\\/\",\"name\":\"CVE-2025-54482: Critical Stack-Based Buffer Overflow Vulnerability in The Biosig Project libbiosig - Ameeba Blog\",\"description\":\"Overview A critical vulnerability has been discovered in the Biosig Project libbiosig software, specific to its MFER parsing functionality. This vulnerability, tagged as CVE-2025-54482, exposes systems to potential compromise and data leakage. By exploiting this flaw, an attacker can execute arbitrary code, thereby gaining unauthorized access to sensitive data or control over the system. This\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/cve-2025-54482-critical-stack-based-buffer-overflow-vulnerability-in-the-biosig-project-libbiosig\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/author\\\/admin\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/author\\\/admin\\\/#author\"},\"datePublished\":\"2025-08-30T13:03:51+00:00\",\"dateModified\":\"2025-09-16T11:36:42+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/\",\"name\":\"Ameeba Blog\",\"description\":\"Your Guide to a Safer Digital World.\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"CVE-2025-54482: Critical Stack-Based Buffer Overflow Vulnerability in The Biosig Project libbiosig - Ameeba Blog","description":"Overview A critical vulnerability has been discovered in the Biosig Project libbiosig software, specific to its MFER parsing functionality. This vulnerability, tagged as CVE-2025-54482, exposes systems to potential compromise and data leakage. By exploiting this flaw, an attacker can execute arbitrary code, thereby gaining unauthorized access to sensitive data or control over the system. This","canonical_url":"https:\/\/www.ameeba.com\/blog\/cve-2025-54482-critical-stack-based-buffer-overflow-vulnerability-in-the-biosig-project-libbiosig\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/www.ameeba.com\/blog\/cve-2025-54482-critical-stack-based-buffer-overflow-vulnerability-in-the-biosig-project-libbiosig\/#blogposting","name":"CVE-2025-54482: Critical Stack-Based Buffer Overflow Vulnerability in The Biosig Project libbiosig - Ameeba Blog","headline":"CVE-2025-54482: Critical Stack-Based Buffer Overflow Vulnerability in The Biosig Project libbiosig","author":{"@id":"https:\/\/www.ameeba.com\/blog\/author\/admin\/#author"},"publisher":{"@id":"https:\/\/www.ameeba.com\/blog\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/www.ameeba.com\/blog\/wp-content\/uploads\/2025\/02\/image-5.png","@id":"https:\/\/www.ameeba.com\/blog\/#articleImage"},"datePublished":"2025-08-30T13:03:51+00:00","dateModified":"2025-09-16T11:36:42+00:00","inLanguage":"en-US","mainEntityOfPage":{"@id":"https:\/\/www.ameeba.com\/blog\/cve-2025-54482-critical-stack-based-buffer-overflow-vulnerability-in-the-biosig-project-libbiosig\/#webpage"},"isPartOf":{"@id":"https:\/\/www.ameeba.com\/blog\/cve-2025-54482-critical-stack-based-buffer-overflow-vulnerability-in-the-biosig-project-libbiosig\/#webpage"},"articleSection":"Uncategorized, Buffer Overflow, Rce"},{"@type":"BreadcrumbList","@id":"https:\/\/www.ameeba.com\/blog\/cve-2025-54482-critical-stack-based-buffer-overflow-vulnerability-in-the-biosig-project-libbiosig\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/www.ameeba.com\/blog\/#listItem","position":1,"name":"Home","item":"https:\/\/www.ameeba.com\/blog\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.ameeba.com\/blog\/category\/uncategorized\/#listItem","name":"Uncategorized"}},{"@type":"ListItem","@id":"https:\/\/www.ameeba.com\/blog\/category\/uncategorized\/#listItem","position":2,"name":"Uncategorized","item":"https:\/\/www.ameeba.com\/blog\/category\/uncategorized\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.ameeba.com\/blog\/cve-2025-54482-critical-stack-based-buffer-overflow-vulnerability-in-the-biosig-project-libbiosig\/#listItem","name":"CVE-2025-54482: Critical Stack-Based Buffer Overflow Vulnerability in The Biosig Project libbiosig"},"previousItem":{"@type":"ListItem","@id":"https:\/\/www.ameeba.com\/blog\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/www.ameeba.com\/blog\/cve-2025-54482-critical-stack-based-buffer-overflow-vulnerability-in-the-biosig-project-libbiosig\/#listItem","position":3,"name":"CVE-2025-54482: Critical Stack-Based Buffer Overflow Vulnerability in The Biosig Project libbiosig","previousItem":{"@type":"ListItem","@id":"https:\/\/www.ameeba.com\/blog\/category\/uncategorized\/#listItem","name":"Uncategorized"}}]},{"@type":"Organization","@id":"https:\/\/www.ameeba.com\/blog\/#organization","name":"Ameeba Blog","description":"Your Guide to a Safer Digital World.","url":"https:\/\/www.ameeba.com\/blog\/","logo":{"@type":"ImageObject","url":"https:\/\/www.ameeba.com\/blog\/wp-content\/uploads\/2025\/02\/image-5.png","@id":"https:\/\/www.ameeba.com\/blog\/cve-2025-54482-critical-stack-based-buffer-overflow-vulnerability-in-the-biosig-project-libbiosig\/#organizationLogo"},"image":{"@id":"https:\/\/www.ameeba.com\/blog\/cve-2025-54482-critical-stack-based-buffer-overflow-vulnerability-in-the-biosig-project-libbiosig\/#organizationLogo"}},{"@type":"Person","@id":"https:\/\/www.ameeba.com\/blog\/author\/admin\/#author","url":"https:\/\/www.ameeba.com\/blog\/author\/admin\/","name":"Ameeba","image":{"@type":"ImageObject","@id":"https:\/\/www.ameeba.com\/blog\/cve-2025-54482-critical-stack-based-buffer-overflow-vulnerability-in-the-biosig-project-libbiosig\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/ead225eeac23a6207666b4137a84523c6b550501a7ee49c81559ebd727825560?s=96&d=mm&r=g","width":96,"height":96,"caption":"Ameeba"}},{"@type":"WebPage","@id":"https:\/\/www.ameeba.com\/blog\/cve-2025-54482-critical-stack-based-buffer-overflow-vulnerability-in-the-biosig-project-libbiosig\/#webpage","url":"https:\/\/www.ameeba.com\/blog\/cve-2025-54482-critical-stack-based-buffer-overflow-vulnerability-in-the-biosig-project-libbiosig\/","name":"CVE-2025-54482: Critical Stack-Based Buffer Overflow Vulnerability in The Biosig Project libbiosig - Ameeba Blog","description":"Overview A critical vulnerability has been discovered in the Biosig Project libbiosig software, specific to its MFER parsing functionality. This vulnerability, tagged as CVE-2025-54482, exposes systems to potential compromise and data leakage. By exploiting this flaw, an attacker can execute arbitrary code, thereby gaining unauthorized access to sensitive data or control over the system. This","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/www.ameeba.com\/blog\/#website"},"breadcrumb":{"@id":"https:\/\/www.ameeba.com\/blog\/cve-2025-54482-critical-stack-based-buffer-overflow-vulnerability-in-the-biosig-project-libbiosig\/#breadcrumblist"},"author":{"@id":"https:\/\/www.ameeba.com\/blog\/author\/admin\/#author"},"creator":{"@id":"https:\/\/www.ameeba.com\/blog\/author\/admin\/#author"},"datePublished":"2025-08-30T13:03:51+00:00","dateModified":"2025-09-16T11:36:42+00:00"},{"@type":"WebSite","@id":"https:\/\/www.ameeba.com\/blog\/#website","url":"https:\/\/www.ameeba.com\/blog\/","name":"Ameeba Blog","description":"Your Guide to a Safer Digital World.","inLanguage":"en-US","publisher":{"@id":"https:\/\/www.ameeba.com\/blog\/#organization"}}]},"og:locale":"en_US","og:site_name":"Ameeba Blog - Your Guide to a Safer Digital World.","og:type":"article","og:title":"CVE-2025-54482: Critical Stack-Based Buffer Overflow Vulnerability in The Biosig Project libbiosig - Ameeba Blog","og:description":"Overview A critical vulnerability has been discovered in the Biosig Project libbiosig software, specific to its MFER parsing functionality. This vulnerability, tagged as CVE-2025-54482, exposes systems to potential compromise and data leakage. By exploiting this flaw, an attacker can execute arbitrary code, thereby gaining unauthorized access to sensitive data or control over the system. This","og:url":"https:\/\/www.ameeba.com\/blog\/cve-2025-54482-critical-stack-based-buffer-overflow-vulnerability-in-the-biosig-project-libbiosig\/","og:image":"https:\/\/www.ameeba.com\/blog\/wp-content\/uploads\/2025\/02\/image-5.png","og:image:secure_url":"https:\/\/www.ameeba.com\/blog\/wp-content\/uploads\/2025\/02\/image-5.png","article:published_time":"2025-08-30T13:03:51+00:00","article:modified_time":"2025-09-16T17:36:42+00:00","twitter:card":"summary_large_image","twitter:title":"CVE-2025-54482: Critical Stack-Based Buffer Overflow Vulnerability in The Biosig Project libbiosig - Ameeba Blog","twitter:description":"Overview A critical vulnerability has been discovered in the Biosig Project libbiosig software, specific to its MFER parsing functionality. This vulnerability, tagged as CVE-2025-54482, exposes systems to potential compromise and data leakage. By exploiting this flaw, an attacker can execute arbitrary code, thereby gaining unauthorized access to sensitive data or control over the system. This","twitter:image":"https:\/\/www.ameeba.com\/blog\/wp-content\/uploads\/2025\/02\/image-5.png"},"aioseo_meta_data":{"post_id":"68124","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"limit_modified_date":false,"created":"2025-08-30 18:04:37","updated":"2026-06-30 03:17:36","focus_keyword":null,"additional_keywords":null,"truseo_locale":null,"ai":null,"breadcrumb_settings":null,"seo_analyzer_scan_date":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/www.ameeba.com\/blog\/\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/www.ameeba.com\/blog\/category\/uncategorized\/\" title=\"Uncategorized\">Uncategorized<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<strong>CVE-2025-54482: Critical Stack-Based Buffer Overflow Vulnerability in The Biosig Project libbiosig<\/strong>\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/www.ameeba.com\/blog\/"},{"label":"Uncategorized","link":"https:\/\/www.ameeba.com\/blog\/category\/uncategorized\/"},{"label":"<strong>CVE-2025-54482: Critical Stack-Based Buffer Overflow Vulnerability in The Biosig Project libbiosig<\/strong>","link":"https:\/\/www.ameeba.com\/blog\/cve-2025-54482-critical-stack-based-buffer-overflow-vulnerability-in-the-biosig-project-libbiosig\/"}],"_links":{"self":[{"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/posts\/68124","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/comments?post=68124"}],"version-history":[{"count":0,"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/posts\/68124\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/media?parent=68124"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/categories?post=68124"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/tags?post=68124"},{"taxonomy":"vendor","embeddable":true,"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/vendor?post=68124"},{"taxonomy":"product","embeddable":true,"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/product?post=68124"},{"taxonomy":"attack_vector","embeddable":true,"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/attack_vector?post=68124"},{"taxonomy":"asset_type","embeddable":true,"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/asset_type?post=68124"},{"taxonomy":"severity","embeddable":true,"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/severity?post=68124"},{"taxonomy":"exploit_status","embeddable":true,"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/exploit_status?post=68124"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}