{"id":59475,"date":"2025-07-18T19:53:41","date_gmt":"2025-07-18T19:53:41","guid":{"rendered":""},"modified":"2025-08-09T12:20:24","modified_gmt":"2025-08-09T18:20:24","slug":"cve-2025-7530-critical-stack-based-buffer-overflow-vulnerability-in-tenda-fh1202","status":"publish","type":"post","link":"https:\/\/www.ameeba.com\/blog\/cve-2025-7530-critical-stack-based-buffer-overflow-vulnerability-in-tenda-fh1202\/","title":{"rendered":"<strong>CVE-2025-7530: Critical Stack-Based Buffer Overflow Vulnerability in Tenda FH1202<\/strong>"},"content":{"rendered":"<p><strong>Overview<\/strong><\/p>\n<p>The Common Vulnerabilities and Exposures (CVE) system has identified a critical stack-based buffer overflow vulnerability, designated as CVE-2025-7530, in Tenda FH1202 version 1.2.0.14(408). This vulnerability exposes systems to potential compromise and data leakage, posing a significant risk to users. The flaw resides in the fromPptpUserAdd function of the \/goform\/PPTPDClient file, and the manipulation of the Username argument can trigger it. Given the severity of the impact and the fact that the exploit has been publicized, immediate action is required from users and administrators of affected systems.<\/p>\n<p><strong>Vulnerability Summary<\/strong><\/p>\n<p>CVE ID: CVE-2025-7530<br \/>\nSeverity: Critical (8.8 CVSS Severity Score)<br \/>\nAttack Vector: Network<br \/>\nPrivileges Required: None<br \/>\nUser Interaction: None<br \/>\nImpact: <a href=\"https:\/\/www.ameeba.com\/blog\/cve-2025-7837-critical-vulnerability-in-totolink-t6-potentially-leading-to-system-compromise\/\"  data-wpil-monitor-id=\"71022\">Potential system<\/a> compromise or data leakage<\/p>\n<p><strong>Affected Products<\/strong><\/p>\n<p>Product | Affected Versions<\/p>\n<p>Tenda FH1202 | 1.2.0.14(408)<\/p>\n<p><strong>How the Exploit Works<\/strong><\/p>\n<p>The <a href=\"https:\/\/www.ameeba.com\/blog\/cve-2025-49886-critical-php-local-file-inclusion-vulnerability-in-webgeniuslab-zikzag-core\/\"  data-wpil-monitor-id=\"66135\">vulnerability resides in the fromPptpUserAdd function of the \/goform\/PPTPDClient file<\/a> within the Tenda FH1202 firmware. A <a href=\"https:\/\/www.ameeba.com\/blog\/cve-2025-28946-php-remote-file-inclusion-vulnerability-in-bzotheme-printxtore\/\"  data-wpil-monitor-id=\"66165\">remote attacker can exploit this vulnerability<\/a> by sending specially crafted data that manipulates the Username argument within this function. As the Username argument is not properly validated, this input results in a stack-based <a href=\"https:\/\/www.ameeba.com\/blog\/cve-2025-7596-critical-remote-buffer-overflow-vulnerability-in-tenda-fh1205\/\"  data-wpil-monitor-id=\"66411\">buffer overflow<\/a> condition. This overflow can allow the attacker to execute arbitrary code, <a href=\"https:\/\/www.ameeba.com\/blog\/cve-2025-7793-critical-vulnerability-in-tenda-fh451-leading-to-system-compromise\/\"  data-wpil-monitor-id=\"68493\">leading to full system<\/a> compromise or data leakage.<\/p>\n<p><strong>Conceptual Example Code<\/strong><\/p>\n<p>Below is a conceptual example of how the vulnerability might be exploited. This is a pseudo HTTP POST request to the vulnerable endpoint, carrying a malicious payload that manipulates the Username argument to trigger the <a href=\"https:\/\/www.ameeba.com\/blog\/cve-2025-7597-critical-stack-based-buffer-overflow-vulnerability-in-tenda-ax1803-1-0-0-1\/\"  data-wpil-monitor-id=\"66925\">buffer overflow<\/a>:<\/p>\n<pre><code class=\"language-http\">POST \/goform\/PPTPDClient?fromPptpUserAdd HTTP\/1.1\nHost: target.example.com\nContent-Type: application\/x-www-form-urlencoded\nusername=AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA...&password=guest123<\/code><\/pre>\n<p>In this example, &#8216;A&#8217; is repeated multiple times to <a href=\"https:\/\/www.ameeba.com\/blog\/cve-2025-8168-critical-buffer-overflow-vulnerability-in-d-link-dir-513-1-10\/\"  data-wpil-monitor-id=\"67083\">overflow the username buffer<\/a>. This is a simplified example and actual exploitation would require crafting a payload that <a href=\"https:\/\/www.ameeba.com\/blog\/cve-2025-25214-race-condition-vulnerability-in-wwbn-avideo-14-4-leading-to-arbitrary-code-execution\/\"  data-wpil-monitor-id=\"68494\">leads to arbitrary code<\/a> execution.<\/p>\n<p><strong>Mitigation Guidance<\/strong><\/p>\n<p>Users and administrators are strongly encouraged to apply the vendor-provided patch to mitigate this vulnerability immediately. If a patch cannot be applied immediately, implementing a Web Application Firewall (WAF) or an Intrusion Detection System (IDS) can provide temporary mitigation. These solutions can help detect and block exploitation attempts. It&#8217;s also recommended to <a href=\"https:\/\/www.ameeba.com\/blog\/cve-2025-7401-critical-file-read-write-vulnerability-in-premium-age-verification-restriction-for-wordpress-plugin\/\"  data-wpil-monitor-id=\"66519\">restrict access to the vulnerable<\/a> system until the patch is applied to reduce the risk of exploitation.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Overview The Common Vulnerabilities and Exposures (CVE) system has identified a critical stack-based buffer overflow vulnerability, designated as CVE-2025-7530, in Tenda FH1202 version 1.2.0.14(408). This vulnerability exposes systems to potential compromise and data leakage, posing a significant risk to users. The flaw resides in the fromPptpUserAdd function of the \/goform\/PPTPDClient file, and the manipulation of [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false,"footnotes":""},"categories":[1],"tags":[],"vendor":[],"product":[],"attack_vector":[86,80],"asset_type":[],"severity":[],"exploit_status":[],"class_list":["post-59475","post","type-post","status-publish","format-standard","hentry","category-uncategorized","attack_vector-buffer-overflow","attack_vector-rce"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.4 - aioseo.com -->\n\t<meta name=\"description\" content=\"Overview The Common Vulnerabilities and Exposures (CVE) system has identified a critical stack-based buffer overflow vulnerability, designated as CVE-2025-7530, in Tenda FH1202 version 1.2.0.14(408). This vulnerability exposes systems to potential compromise and data leakage, posing a significant risk to users. The flaw resides in the fromPptpUserAdd function of the \/goform\/PPTPDClient file, and the manipulation of\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Ameeba\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/www.ameeba.com\/blog\/cve-2025-7530-critical-stack-based-buffer-overflow-vulnerability-in-tenda-fh1202\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.4\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Ameeba Blog - Your Guide to a Safer Digital World.\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"CVE-2025-7530: Critical Stack-Based Buffer Overflow Vulnerability in Tenda FH1202 - Ameeba Blog\" \/>\n\t\t<meta property=\"og:description\" content=\"Overview The Common Vulnerabilities and Exposures (CVE) system has identified a critical stack-based buffer overflow vulnerability, designated as CVE-2025-7530, in Tenda FH1202 version 1.2.0.14(408). This vulnerability exposes systems to potential compromise and data leakage, posing a significant risk to users. The flaw resides in the fromPptpUserAdd function of the \/goform\/PPTPDClient file, and the manipulation of\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/www.ameeba.com\/blog\/cve-2025-7530-critical-stack-based-buffer-overflow-vulnerability-in-tenda-fh1202\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/www.ameeba.com\/blog\/wp-content\/uploads\/2025\/02\/image-5.png\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/www.ameeba.com\/blog\/wp-content\/uploads\/2025\/02\/image-5.png\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2025-07-18T19:53:41+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2025-08-09T18:20:24+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"CVE-2025-7530: Critical Stack-Based Buffer Overflow Vulnerability in Tenda FH1202 - Ameeba Blog\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Overview The Common Vulnerabilities and Exposures (CVE) system has identified a critical stack-based buffer overflow vulnerability, designated as CVE-2025-7530, in Tenda FH1202 version 1.2.0.14(408). This vulnerability exposes systems to potential compromise and data leakage, posing a significant risk to users. The flaw resides in the fromPptpUserAdd function of the \/goform\/PPTPDClient file, and the manipulation of\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/www.ameeba.com\/blog\/wp-content\/uploads\/2025\/02\/image-5.png\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/cve-2025-7530-critical-stack-based-buffer-overflow-vulnerability-in-tenda-fh1202\\\/#blogposting\",\"name\":\"CVE-2025-7530: Critical Stack-Based Buffer Overflow Vulnerability in Tenda FH1202 - Ameeba Blog\",\"headline\":\"CVE-2025-7530: Critical Stack-Based Buffer Overflow Vulnerability in Tenda FH1202\",\"author\":{\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/author\\\/admin\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/wp-content\\\/uploads\\\/2025\\\/02\\\/image-5.png\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/#articleImage\"},\"datePublished\":\"2025-07-18T19:53:41+00:00\",\"dateModified\":\"2025-08-09T12:20:24+00:00\",\"inLanguage\":\"en-US\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/cve-2025-7530-critical-stack-based-buffer-overflow-vulnerability-in-tenda-fh1202\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/cve-2025-7530-critical-stack-based-buffer-overflow-vulnerability-in-tenda-fh1202\\\/#webpage\"},\"articleSection\":\"Uncategorized, Buffer Overflow, Rce\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/cve-2025-7530-critical-stack-based-buffer-overflow-vulnerability-in-tenda-fh1202\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/category\\\/uncategorized\\\/#listItem\",\"name\":\"Uncategorized\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/category\\\/uncategorized\\\/#listItem\",\"position\":2,\"name\":\"Uncategorized\",\"item\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/category\\\/uncategorized\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/cve-2025-7530-critical-stack-based-buffer-overflow-vulnerability-in-tenda-fh1202\\\/#listItem\",\"name\":\"CVE-2025-7530: Critical Stack-Based Buffer Overflow Vulnerability in Tenda FH1202\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/cve-2025-7530-critical-stack-based-buffer-overflow-vulnerability-in-tenda-fh1202\\\/#listItem\",\"position\":3,\"name\":\"CVE-2025-7530: Critical Stack-Based Buffer Overflow Vulnerability in Tenda FH1202\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/category\\\/uncategorized\\\/#listItem\",\"name\":\"Uncategorized\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/#organization\",\"name\":\"Ameeba Blog\",\"description\":\"Your Guide to a Safer Digital World.\",\"url\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/wp-content\\\/uploads\\\/2025\\\/02\\\/image-5.png\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/cve-2025-7530-critical-stack-based-buffer-overflow-vulnerability-in-tenda-fh1202\\\/#organizationLogo\"},\"image\":{\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/cve-2025-7530-critical-stack-based-buffer-overflow-vulnerability-in-tenda-fh1202\\\/#organizationLogo\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/author\\\/admin\\\/#author\",\"url\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/author\\\/admin\\\/\",\"name\":\"Ameeba\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/cve-2025-7530-critical-stack-based-buffer-overflow-vulnerability-in-tenda-fh1202\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ead225eeac23a6207666b4137a84523c6b550501a7ee49c81559ebd727825560?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"Ameeba\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/cve-2025-7530-critical-stack-based-buffer-overflow-vulnerability-in-tenda-fh1202\\\/#webpage\",\"url\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/cve-2025-7530-critical-stack-based-buffer-overflow-vulnerability-in-tenda-fh1202\\\/\",\"name\":\"CVE-2025-7530: Critical Stack-Based Buffer Overflow Vulnerability in Tenda FH1202 - Ameeba Blog\",\"description\":\"Overview The Common Vulnerabilities and Exposures (CVE) system has identified a critical stack-based buffer overflow vulnerability, designated as CVE-2025-7530, in Tenda FH1202 version 1.2.0.14(408). This vulnerability exposes systems to potential compromise and data leakage, posing a significant risk to users. The flaw resides in the fromPptpUserAdd function of the \\\/goform\\\/PPTPDClient file, and the manipulation of\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/cve-2025-7530-critical-stack-based-buffer-overflow-vulnerability-in-tenda-fh1202\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/author\\\/admin\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/author\\\/admin\\\/#author\"},\"datePublished\":\"2025-07-18T19:53:41+00:00\",\"dateModified\":\"2025-08-09T12:20:24+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/\",\"name\":\"Ameeba Blog\",\"description\":\"Your Guide to a Safer Digital World.\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"CVE-2025-7530: Critical Stack-Based Buffer Overflow Vulnerability in Tenda FH1202 - Ameeba Blog","description":"Overview The Common Vulnerabilities and Exposures (CVE) system has identified a critical stack-based buffer overflow vulnerability, designated as CVE-2025-7530, in Tenda FH1202 version 1.2.0.14(408). This vulnerability exposes systems to potential compromise and data leakage, posing a significant risk to users. The flaw resides in the fromPptpUserAdd function of the \/goform\/PPTPDClient file, and the manipulation of","canonical_url":"https:\/\/www.ameeba.com\/blog\/cve-2025-7530-critical-stack-based-buffer-overflow-vulnerability-in-tenda-fh1202\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/www.ameeba.com\/blog\/cve-2025-7530-critical-stack-based-buffer-overflow-vulnerability-in-tenda-fh1202\/#blogposting","name":"CVE-2025-7530: Critical Stack-Based Buffer Overflow Vulnerability in Tenda FH1202 - Ameeba Blog","headline":"CVE-2025-7530: Critical Stack-Based Buffer Overflow Vulnerability in Tenda FH1202","author":{"@id":"https:\/\/www.ameeba.com\/blog\/author\/admin\/#author"},"publisher":{"@id":"https:\/\/www.ameeba.com\/blog\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/www.ameeba.com\/blog\/wp-content\/uploads\/2025\/02\/image-5.png","@id":"https:\/\/www.ameeba.com\/blog\/#articleImage"},"datePublished":"2025-07-18T19:53:41+00:00","dateModified":"2025-08-09T12:20:24+00:00","inLanguage":"en-US","mainEntityOfPage":{"@id":"https:\/\/www.ameeba.com\/blog\/cve-2025-7530-critical-stack-based-buffer-overflow-vulnerability-in-tenda-fh1202\/#webpage"},"isPartOf":{"@id":"https:\/\/www.ameeba.com\/blog\/cve-2025-7530-critical-stack-based-buffer-overflow-vulnerability-in-tenda-fh1202\/#webpage"},"articleSection":"Uncategorized, Buffer Overflow, Rce"},{"@type":"BreadcrumbList","@id":"https:\/\/www.ameeba.com\/blog\/cve-2025-7530-critical-stack-based-buffer-overflow-vulnerability-in-tenda-fh1202\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/www.ameeba.com\/blog\/#listItem","position":1,"name":"Home","item":"https:\/\/www.ameeba.com\/blog\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.ameeba.com\/blog\/category\/uncategorized\/#listItem","name":"Uncategorized"}},{"@type":"ListItem","@id":"https:\/\/www.ameeba.com\/blog\/category\/uncategorized\/#listItem","position":2,"name":"Uncategorized","item":"https:\/\/www.ameeba.com\/blog\/category\/uncategorized\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.ameeba.com\/blog\/cve-2025-7530-critical-stack-based-buffer-overflow-vulnerability-in-tenda-fh1202\/#listItem","name":"CVE-2025-7530: Critical Stack-Based Buffer Overflow Vulnerability in Tenda FH1202"},"previousItem":{"@type":"ListItem","@id":"https:\/\/www.ameeba.com\/blog\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/www.ameeba.com\/blog\/cve-2025-7530-critical-stack-based-buffer-overflow-vulnerability-in-tenda-fh1202\/#listItem","position":3,"name":"CVE-2025-7530: Critical Stack-Based Buffer Overflow Vulnerability in Tenda FH1202","previousItem":{"@type":"ListItem","@id":"https:\/\/www.ameeba.com\/blog\/category\/uncategorized\/#listItem","name":"Uncategorized"}}]},{"@type":"Organization","@id":"https:\/\/www.ameeba.com\/blog\/#organization","name":"Ameeba Blog","description":"Your Guide to a Safer Digital World.","url":"https:\/\/www.ameeba.com\/blog\/","logo":{"@type":"ImageObject","url":"https:\/\/www.ameeba.com\/blog\/wp-content\/uploads\/2025\/02\/image-5.png","@id":"https:\/\/www.ameeba.com\/blog\/cve-2025-7530-critical-stack-based-buffer-overflow-vulnerability-in-tenda-fh1202\/#organizationLogo"},"image":{"@id":"https:\/\/www.ameeba.com\/blog\/cve-2025-7530-critical-stack-based-buffer-overflow-vulnerability-in-tenda-fh1202\/#organizationLogo"}},{"@type":"Person","@id":"https:\/\/www.ameeba.com\/blog\/author\/admin\/#author","url":"https:\/\/www.ameeba.com\/blog\/author\/admin\/","name":"Ameeba","image":{"@type":"ImageObject","@id":"https:\/\/www.ameeba.com\/blog\/cve-2025-7530-critical-stack-based-buffer-overflow-vulnerability-in-tenda-fh1202\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/ead225eeac23a6207666b4137a84523c6b550501a7ee49c81559ebd727825560?s=96&d=mm&r=g","width":96,"height":96,"caption":"Ameeba"}},{"@type":"WebPage","@id":"https:\/\/www.ameeba.com\/blog\/cve-2025-7530-critical-stack-based-buffer-overflow-vulnerability-in-tenda-fh1202\/#webpage","url":"https:\/\/www.ameeba.com\/blog\/cve-2025-7530-critical-stack-based-buffer-overflow-vulnerability-in-tenda-fh1202\/","name":"CVE-2025-7530: Critical Stack-Based Buffer Overflow Vulnerability in Tenda FH1202 - Ameeba Blog","description":"Overview The Common Vulnerabilities and Exposures (CVE) system has identified a critical stack-based buffer overflow vulnerability, designated as CVE-2025-7530, in Tenda FH1202 version 1.2.0.14(408). This vulnerability exposes systems to potential compromise and data leakage, posing a significant risk to users. The flaw resides in the fromPptpUserAdd function of the \/goform\/PPTPDClient file, and the manipulation of","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/www.ameeba.com\/blog\/#website"},"breadcrumb":{"@id":"https:\/\/www.ameeba.com\/blog\/cve-2025-7530-critical-stack-based-buffer-overflow-vulnerability-in-tenda-fh1202\/#breadcrumblist"},"author":{"@id":"https:\/\/www.ameeba.com\/blog\/author\/admin\/#author"},"creator":{"@id":"https:\/\/www.ameeba.com\/blog\/author\/admin\/#author"},"datePublished":"2025-07-18T19:53:41+00:00","dateModified":"2025-08-09T12:20:24+00:00"},{"@type":"WebSite","@id":"https:\/\/www.ameeba.com\/blog\/#website","url":"https:\/\/www.ameeba.com\/blog\/","name":"Ameeba Blog","description":"Your Guide to a Safer Digital World.","inLanguage":"en-US","publisher":{"@id":"https:\/\/www.ameeba.com\/blog\/#organization"}}]},"og:locale":"en_US","og:site_name":"Ameeba Blog - Your Guide to a Safer Digital World.","og:type":"article","og:title":"CVE-2025-7530: Critical Stack-Based Buffer Overflow Vulnerability in Tenda FH1202 - Ameeba Blog","og:description":"Overview The Common Vulnerabilities and Exposures (CVE) system has identified a critical stack-based buffer overflow vulnerability, designated as CVE-2025-7530, in Tenda FH1202 version 1.2.0.14(408). This vulnerability exposes systems to potential compromise and data leakage, posing a significant risk to users. The flaw resides in the fromPptpUserAdd function of the \/goform\/PPTPDClient file, and the manipulation of","og:url":"https:\/\/www.ameeba.com\/blog\/cve-2025-7530-critical-stack-based-buffer-overflow-vulnerability-in-tenda-fh1202\/","og:image":"https:\/\/www.ameeba.com\/blog\/wp-content\/uploads\/2025\/02\/image-5.png","og:image:secure_url":"https:\/\/www.ameeba.com\/blog\/wp-content\/uploads\/2025\/02\/image-5.png","article:published_time":"2025-07-18T19:53:41+00:00","article:modified_time":"2025-08-09T18:20:24+00:00","twitter:card":"summary_large_image","twitter:title":"CVE-2025-7530: Critical Stack-Based Buffer Overflow Vulnerability in Tenda FH1202 - Ameeba Blog","twitter:description":"Overview The Common Vulnerabilities and Exposures (CVE) system has identified a critical stack-based buffer overflow vulnerability, designated as CVE-2025-7530, in Tenda FH1202 version 1.2.0.14(408). This vulnerability exposes systems to potential compromise and data leakage, posing a significant risk to users. The flaw resides in the fromPptpUserAdd function of the \/goform\/PPTPDClient file, and the manipulation of","twitter:image":"https:\/\/www.ameeba.com\/blog\/wp-content\/uploads\/2025\/02\/image-5.png"},"aioseo_meta_data":{"post_id":"59475","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"limit_modified_date":false,"created":"2025-07-19 01:02:04","updated":"2026-05-31 00:11:18","focus_keyword":null,"additional_keywords":null,"truseo_locale":null,"ai":null,"breadcrumb_settings":null,"seo_analyzer_scan_date":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/www.ameeba.com\/blog\/\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/www.ameeba.com\/blog\/category\/uncategorized\/\" title=\"Uncategorized\">Uncategorized<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<strong>CVE-2025-7530: Critical Stack-Based Buffer Overflow Vulnerability in Tenda FH1202<\/strong>\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/www.ameeba.com\/blog\/"},{"label":"Uncategorized","link":"https:\/\/www.ameeba.com\/blog\/category\/uncategorized\/"},{"label":"<strong>CVE-2025-7530: Critical Stack-Based Buffer Overflow Vulnerability in Tenda FH1202<\/strong>","link":"https:\/\/www.ameeba.com\/blog\/cve-2025-7530-critical-stack-based-buffer-overflow-vulnerability-in-tenda-fh1202\/"}],"_links":{"self":[{"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/posts\/59475","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/comments?post=59475"}],"version-history":[{"count":0,"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/posts\/59475\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/media?parent=59475"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/categories?post=59475"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/tags?post=59475"},{"taxonomy":"vendor","embeddable":true,"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/vendor?post=59475"},{"taxonomy":"product","embeddable":true,"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/product?post=59475"},{"taxonomy":"attack_vector","embeddable":true,"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/attack_vector?post=59475"},{"taxonomy":"asset_type","embeddable":true,"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/asset_type?post=59475"},{"taxonomy":"severity","embeddable":true,"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/severity?post=59475"},{"taxonomy":"exploit_status","embeddable":true,"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/exploit_status?post=59475"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}