{"id":59473,"date":"2025-07-18T17:52:49","date_gmt":"2025-07-18T17:52:49","guid":{"rendered":""},"modified":"2025-09-03T19:03:39","modified_gmt":"2025-09-04T01:03:39","slug":"cve-2025-7528-critical-buffer-overflow-vulnerability-in-tenda-fh1202-1-2-0-14-408","status":"publish","type":"post","link":"https:\/\/www.ameeba.com\/blog\/cve-2025-7528-critical-buffer-overflow-vulnerability-in-tenda-fh1202-1-2-0-14-408\/","title":{"rendered":"<strong>CVE-2025-7528: Critical Buffer Overflow Vulnerability in Tenda FH1202 1.2.0.14(408)<\/strong>"},"content":{"rendered":"<p><strong>Overview<\/strong><\/p>\n<p>The cybersecurity landscape is constantly evolving with new vulnerabilities being discovered daily. One such critical vulnerability has been found in the Tenda FH1202 1.2.0.14(408) router model, specifically within the \/goform\/GstDhcpSetSer file. This <a href=\"https:\/\/www.ameeba.com\/blog\/cve-2025-52808-a-critical-php-remote-file-inclusion-vulnerability-in-realtyelite\/\"  data-wpil-monitor-id=\"65908\">vulnerability is considered critical due to its potential for remote<\/a> code execution, which could lead to system compromise or data leakage. The router&#8217;s wide usage in both home and business environments underlines the <a href=\"https:\/\/www.ameeba.com\/blog\/cve-2025-47998-severe-heap-based-buffer-overflow-vulnerability-in-windows-routing-and-remote-access-service\/\"  data-wpil-monitor-id=\"67337\">severity of this vulnerability<\/a> and its potential for widespread damage.<\/p>\n<p><strong>Vulnerability Summary<\/strong><\/p>\n<p>CVE ID: CVE-2025-7528<br \/>\nSeverity: Critical, CVSS Severity Score: 8.8<br \/>\nAttack Vector: Network<br \/>\nPrivileges Required: None<br \/>\nUser Interaction: None<br \/>\nImpact: <a href=\"https:\/\/www.ameeba.com\/blog\/cve-2025-7837-critical-vulnerability-in-totolink-t6-potentially-leading-to-system-compromise\/\"  data-wpil-monitor-id=\"71025\">Potential system<\/a> compromise or data leakage<\/p>\n<p><strong>Affected Products<\/strong><\/p>\n<p>Product | Affected Versions<\/p>\n<p>Tenda FH1202 | 1.2.0.14(408)<\/p>\n<p><strong>How the Exploit Works<\/strong><\/p>\n<p>The <a href=\"https:\/\/www.ameeba.com\/blog\/cve-2025-49416-critical-php-remote-file-inclusion-vulnerability-in-fastw3b-llc-fw-gallery\/\"  data-wpil-monitor-id=\"66080\">vulnerability lies in the function fromGstDhcpSetSer of the file<\/a> \/goform\/GstDhcpSetSer. The manipulation of the argument &#8216;dips&#8217; leads to a stack-based <a href=\"https:\/\/www.ameeba.com\/blog\/cve-2025-7596-critical-remote-buffer-overflow-vulnerability-in-tenda-fh1205\/\"  data-wpil-monitor-id=\"66413\">buffer overflow<\/a>. This overflow can result in the <a href=\"https:\/\/www.ameeba.com\/blog\/cve-2025-26074-remote-code-execution-vulnerability-in-orkes-conductor-v3-21-11\/\"  data-wpil-monitor-id=\"66081\">execution of arbitrary code<\/a> due to the corruption of critical data structures. As it is possible to launch the exploit remotely, an attacker can <a href=\"https:\/\/www.ameeba.com\/blog\/cve-2025-50160-heap-based-buffer-overflow-in-windows-rras-posing-system-compromise-risk\/\"  data-wpil-monitor-id=\"78466\">compromise the system<\/a> without requiring any user interaction.<\/p>\n<p><strong>Conceptual Example Code<\/strong><\/p>\n<p>A conceptual example demonstrating the exploitation of this vulnerability could look like this:<\/p>\n<pre><code class=\"language-http\">POST \/goform\/GstDhcpSetSer HTTP\/1.1\nHost: target_router_ip\nContent-Type: application\/x-www-form-urlencoded\ndips=AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA...<\/code><\/pre>\n<p>In the above example, the &#8216;dips&#8217; argument is manipulated with a long string of &#8216;A&#8217;s causing a <a href=\"https:\/\/www.ameeba.com\/blog\/cve-2025-7597-critical-stack-based-buffer-overflow-vulnerability-in-tenda-ax1803-1-0-0-1\/\"  data-wpil-monitor-id=\"66949\">buffer overflow<\/a>.<\/p>\n<p><strong>Mitigation<\/strong><\/p>\n<p><a href=\"https:\/\/www.ameeba.com\/blog\/cve-2025-7805-critical-vulnerability-in-tenda-fh451-1-0-0-9-leading-to-remote-buffer-overflow-attacks\/\"  data-wpil-monitor-id=\"67640\">Tenda has released a patch to address this vulnerability<\/a>. Users are strongly urged to update their devices to the latest firmware version as soon as possible. For temporary mitigation, a Web Application Firewall (WAF) or Intrusion Detection System (IDS) can be used to <a href=\"https:\/\/www.ameeba.com\/blog\/cve-2025-20217-denial-of-service-vulnerability-in-snort-3-detection-engine-of-cisco-secure-firewall-threat-defense-software\/\"  data-wpil-monitor-id=\"77007\">detect and prevent attempts to exploit this vulnerability<\/a>. However, these are not long-term solutions, and the device&#8217;s firmware should be updated as soon as feasible.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Overview The cybersecurity landscape is constantly evolving with new vulnerabilities being discovered daily. One such critical vulnerability has been found in the Tenda FH1202 1.2.0.14(408) router model, specifically within the \/goform\/GstDhcpSetSer file. This vulnerability is considered critical due to its potential for remote code execution, which could lead to system compromise or data leakage. The [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false,"footnotes":""},"categories":[1],"tags":[],"vendor":[],"product":[],"attack_vector":[86,80],"asset_type":[],"severity":[],"exploit_status":[],"class_list":["post-59473","post","type-post","status-publish","format-standard","hentry","category-uncategorized","attack_vector-buffer-overflow","attack_vector-rce"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.4 - aioseo.com -->\n\t<meta name=\"description\" content=\"Overview The cybersecurity landscape is constantly evolving with new vulnerabilities being discovered daily. One such critical vulnerability has been found in the Tenda FH1202 1.2.0.14(408) router model, specifically within the \/goform\/GstDhcpSetSer file. This vulnerability is considered critical due to its potential for remote code execution, which could lead to system compromise or data leakage. The\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Ameeba\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/www.ameeba.com\/blog\/cve-2025-7528-critical-buffer-overflow-vulnerability-in-tenda-fh1202-1-2-0-14-408\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.4\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Ameeba Blog - Your Guide to a Safer Digital World.\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"CVE-2025-7528: Critical Buffer Overflow Vulnerability in Tenda FH1202 1.2.0.14(408) - Ameeba Blog\" \/>\n\t\t<meta property=\"og:description\" content=\"Overview The cybersecurity landscape is constantly evolving with new vulnerabilities being discovered daily. One such critical vulnerability has been found in the Tenda FH1202 1.2.0.14(408) router model, specifically within the \/goform\/GstDhcpSetSer file. This vulnerability is considered critical due to its potential for remote code execution, which could lead to system compromise or data leakage. The\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/www.ameeba.com\/blog\/cve-2025-7528-critical-buffer-overflow-vulnerability-in-tenda-fh1202-1-2-0-14-408\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/www.ameeba.com\/blog\/wp-content\/uploads\/2025\/02\/image-5.png\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/www.ameeba.com\/blog\/wp-content\/uploads\/2025\/02\/image-5.png\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2025-07-18T17:52:49+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2025-09-04T01:03:39+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"CVE-2025-7528: Critical Buffer Overflow Vulnerability in Tenda FH1202 1.2.0.14(408) - Ameeba Blog\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Overview The cybersecurity landscape is constantly evolving with new vulnerabilities being discovered daily. One such critical vulnerability has been found in the Tenda FH1202 1.2.0.14(408) router model, specifically within the \/goform\/GstDhcpSetSer file. This vulnerability is considered critical due to its potential for remote code execution, which could lead to system compromise or data leakage. The\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/www.ameeba.com\/blog\/wp-content\/uploads\/2025\/02\/image-5.png\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/cve-2025-7528-critical-buffer-overflow-vulnerability-in-tenda-fh1202-1-2-0-14-408\\\/#blogposting\",\"name\":\"CVE-2025-7528: Critical Buffer Overflow Vulnerability in Tenda FH1202 1.2.0.14(408) - Ameeba Blog\",\"headline\":\"CVE-2025-7528: Critical Buffer Overflow Vulnerability in Tenda FH1202 1.2.0.14(408)\",\"author\":{\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/author\\\/admin\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/wp-content\\\/uploads\\\/2025\\\/02\\\/image-5.png\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/#articleImage\"},\"datePublished\":\"2025-07-18T17:52:49+00:00\",\"dateModified\":\"2025-09-03T19:03:39+00:00\",\"inLanguage\":\"en-US\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/cve-2025-7528-critical-buffer-overflow-vulnerability-in-tenda-fh1202-1-2-0-14-408\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/cve-2025-7528-critical-buffer-overflow-vulnerability-in-tenda-fh1202-1-2-0-14-408\\\/#webpage\"},\"articleSection\":\"Uncategorized, Buffer Overflow, Rce\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/cve-2025-7528-critical-buffer-overflow-vulnerability-in-tenda-fh1202-1-2-0-14-408\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/category\\\/uncategorized\\\/#listItem\",\"name\":\"Uncategorized\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/category\\\/uncategorized\\\/#listItem\",\"position\":2,\"name\":\"Uncategorized\",\"item\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/category\\\/uncategorized\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/cve-2025-7528-critical-buffer-overflow-vulnerability-in-tenda-fh1202-1-2-0-14-408\\\/#listItem\",\"name\":\"CVE-2025-7528: Critical Buffer Overflow Vulnerability in Tenda FH1202 1.2.0.14(408)\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/cve-2025-7528-critical-buffer-overflow-vulnerability-in-tenda-fh1202-1-2-0-14-408\\\/#listItem\",\"position\":3,\"name\":\"CVE-2025-7528: Critical Buffer Overflow Vulnerability in Tenda FH1202 1.2.0.14(408)\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/category\\\/uncategorized\\\/#listItem\",\"name\":\"Uncategorized\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/#organization\",\"name\":\"Ameeba Blog\",\"description\":\"Your Guide to a Safer Digital World.\",\"url\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/wp-content\\\/uploads\\\/2025\\\/02\\\/image-5.png\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/cve-2025-7528-critical-buffer-overflow-vulnerability-in-tenda-fh1202-1-2-0-14-408\\\/#organizationLogo\"},\"image\":{\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/cve-2025-7528-critical-buffer-overflow-vulnerability-in-tenda-fh1202-1-2-0-14-408\\\/#organizationLogo\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/author\\\/admin\\\/#author\",\"url\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/author\\\/admin\\\/\",\"name\":\"Ameeba\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/cve-2025-7528-critical-buffer-overflow-vulnerability-in-tenda-fh1202-1-2-0-14-408\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ead225eeac23a6207666b4137a84523c6b550501a7ee49c81559ebd727825560?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"Ameeba\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/cve-2025-7528-critical-buffer-overflow-vulnerability-in-tenda-fh1202-1-2-0-14-408\\\/#webpage\",\"url\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/cve-2025-7528-critical-buffer-overflow-vulnerability-in-tenda-fh1202-1-2-0-14-408\\\/\",\"name\":\"CVE-2025-7528: Critical Buffer Overflow Vulnerability in Tenda FH1202 1.2.0.14(408) - Ameeba Blog\",\"description\":\"Overview The cybersecurity landscape is constantly evolving with new vulnerabilities being discovered daily. One such critical vulnerability has been found in the Tenda FH1202 1.2.0.14(408) router model, specifically within the \\\/goform\\\/GstDhcpSetSer file. This vulnerability is considered critical due to its potential for remote code execution, which could lead to system compromise or data leakage. The\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/cve-2025-7528-critical-buffer-overflow-vulnerability-in-tenda-fh1202-1-2-0-14-408\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/author\\\/admin\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/author\\\/admin\\\/#author\"},\"datePublished\":\"2025-07-18T17:52:49+00:00\",\"dateModified\":\"2025-09-03T19:03:39+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/\",\"name\":\"Ameeba Blog\",\"description\":\"Your Guide to a Safer Digital World.\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.ameeba.com\\\/blog\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"CVE-2025-7528: Critical Buffer Overflow Vulnerability in Tenda FH1202 1.2.0.14(408) - Ameeba Blog","description":"Overview The cybersecurity landscape is constantly evolving with new vulnerabilities being discovered daily. One such critical vulnerability has been found in the Tenda FH1202 1.2.0.14(408) router model, specifically within the \/goform\/GstDhcpSetSer file. This vulnerability is considered critical due to its potential for remote code execution, which could lead to system compromise or data leakage. The","canonical_url":"https:\/\/www.ameeba.com\/blog\/cve-2025-7528-critical-buffer-overflow-vulnerability-in-tenda-fh1202-1-2-0-14-408\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/www.ameeba.com\/blog\/cve-2025-7528-critical-buffer-overflow-vulnerability-in-tenda-fh1202-1-2-0-14-408\/#blogposting","name":"CVE-2025-7528: Critical Buffer Overflow Vulnerability in Tenda FH1202 1.2.0.14(408) - Ameeba Blog","headline":"CVE-2025-7528: Critical Buffer Overflow Vulnerability in Tenda FH1202 1.2.0.14(408)","author":{"@id":"https:\/\/www.ameeba.com\/blog\/author\/admin\/#author"},"publisher":{"@id":"https:\/\/www.ameeba.com\/blog\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/www.ameeba.com\/blog\/wp-content\/uploads\/2025\/02\/image-5.png","@id":"https:\/\/www.ameeba.com\/blog\/#articleImage"},"datePublished":"2025-07-18T17:52:49+00:00","dateModified":"2025-09-03T19:03:39+00:00","inLanguage":"en-US","mainEntityOfPage":{"@id":"https:\/\/www.ameeba.com\/blog\/cve-2025-7528-critical-buffer-overflow-vulnerability-in-tenda-fh1202-1-2-0-14-408\/#webpage"},"isPartOf":{"@id":"https:\/\/www.ameeba.com\/blog\/cve-2025-7528-critical-buffer-overflow-vulnerability-in-tenda-fh1202-1-2-0-14-408\/#webpage"},"articleSection":"Uncategorized, Buffer Overflow, Rce"},{"@type":"BreadcrumbList","@id":"https:\/\/www.ameeba.com\/blog\/cve-2025-7528-critical-buffer-overflow-vulnerability-in-tenda-fh1202-1-2-0-14-408\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/www.ameeba.com\/blog\/#listItem","position":1,"name":"Home","item":"https:\/\/www.ameeba.com\/blog\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.ameeba.com\/blog\/category\/uncategorized\/#listItem","name":"Uncategorized"}},{"@type":"ListItem","@id":"https:\/\/www.ameeba.com\/blog\/category\/uncategorized\/#listItem","position":2,"name":"Uncategorized","item":"https:\/\/www.ameeba.com\/blog\/category\/uncategorized\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.ameeba.com\/blog\/cve-2025-7528-critical-buffer-overflow-vulnerability-in-tenda-fh1202-1-2-0-14-408\/#listItem","name":"CVE-2025-7528: Critical Buffer Overflow Vulnerability in Tenda FH1202 1.2.0.14(408)"},"previousItem":{"@type":"ListItem","@id":"https:\/\/www.ameeba.com\/blog\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/www.ameeba.com\/blog\/cve-2025-7528-critical-buffer-overflow-vulnerability-in-tenda-fh1202-1-2-0-14-408\/#listItem","position":3,"name":"CVE-2025-7528: Critical Buffer Overflow Vulnerability in Tenda FH1202 1.2.0.14(408)","previousItem":{"@type":"ListItem","@id":"https:\/\/www.ameeba.com\/blog\/category\/uncategorized\/#listItem","name":"Uncategorized"}}]},{"@type":"Organization","@id":"https:\/\/www.ameeba.com\/blog\/#organization","name":"Ameeba Blog","description":"Your Guide to a Safer Digital World.","url":"https:\/\/www.ameeba.com\/blog\/","logo":{"@type":"ImageObject","url":"https:\/\/www.ameeba.com\/blog\/wp-content\/uploads\/2025\/02\/image-5.png","@id":"https:\/\/www.ameeba.com\/blog\/cve-2025-7528-critical-buffer-overflow-vulnerability-in-tenda-fh1202-1-2-0-14-408\/#organizationLogo"},"image":{"@id":"https:\/\/www.ameeba.com\/blog\/cve-2025-7528-critical-buffer-overflow-vulnerability-in-tenda-fh1202-1-2-0-14-408\/#organizationLogo"}},{"@type":"Person","@id":"https:\/\/www.ameeba.com\/blog\/author\/admin\/#author","url":"https:\/\/www.ameeba.com\/blog\/author\/admin\/","name":"Ameeba","image":{"@type":"ImageObject","@id":"https:\/\/www.ameeba.com\/blog\/cve-2025-7528-critical-buffer-overflow-vulnerability-in-tenda-fh1202-1-2-0-14-408\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/ead225eeac23a6207666b4137a84523c6b550501a7ee49c81559ebd727825560?s=96&d=mm&r=g","width":96,"height":96,"caption":"Ameeba"}},{"@type":"WebPage","@id":"https:\/\/www.ameeba.com\/blog\/cve-2025-7528-critical-buffer-overflow-vulnerability-in-tenda-fh1202-1-2-0-14-408\/#webpage","url":"https:\/\/www.ameeba.com\/blog\/cve-2025-7528-critical-buffer-overflow-vulnerability-in-tenda-fh1202-1-2-0-14-408\/","name":"CVE-2025-7528: Critical Buffer Overflow Vulnerability in Tenda FH1202 1.2.0.14(408) - Ameeba Blog","description":"Overview The cybersecurity landscape is constantly evolving with new vulnerabilities being discovered daily. One such critical vulnerability has been found in the Tenda FH1202 1.2.0.14(408) router model, specifically within the \/goform\/GstDhcpSetSer file. This vulnerability is considered critical due to its potential for remote code execution, which could lead to system compromise or data leakage. The","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/www.ameeba.com\/blog\/#website"},"breadcrumb":{"@id":"https:\/\/www.ameeba.com\/blog\/cve-2025-7528-critical-buffer-overflow-vulnerability-in-tenda-fh1202-1-2-0-14-408\/#breadcrumblist"},"author":{"@id":"https:\/\/www.ameeba.com\/blog\/author\/admin\/#author"},"creator":{"@id":"https:\/\/www.ameeba.com\/blog\/author\/admin\/#author"},"datePublished":"2025-07-18T17:52:49+00:00","dateModified":"2025-09-03T19:03:39+00:00"},{"@type":"WebSite","@id":"https:\/\/www.ameeba.com\/blog\/#website","url":"https:\/\/www.ameeba.com\/blog\/","name":"Ameeba Blog","description":"Your Guide to a Safer Digital World.","inLanguage":"en-US","publisher":{"@id":"https:\/\/www.ameeba.com\/blog\/#organization"}}]},"og:locale":"en_US","og:site_name":"Ameeba Blog - Your Guide to a Safer Digital World.","og:type":"article","og:title":"CVE-2025-7528: Critical Buffer Overflow Vulnerability in Tenda FH1202 1.2.0.14(408) - Ameeba Blog","og:description":"Overview The cybersecurity landscape is constantly evolving with new vulnerabilities being discovered daily. One such critical vulnerability has been found in the Tenda FH1202 1.2.0.14(408) router model, specifically within the \/goform\/GstDhcpSetSer file. This vulnerability is considered critical due to its potential for remote code execution, which could lead to system compromise or data leakage. The","og:url":"https:\/\/www.ameeba.com\/blog\/cve-2025-7528-critical-buffer-overflow-vulnerability-in-tenda-fh1202-1-2-0-14-408\/","og:image":"https:\/\/www.ameeba.com\/blog\/wp-content\/uploads\/2025\/02\/image-5.png","og:image:secure_url":"https:\/\/www.ameeba.com\/blog\/wp-content\/uploads\/2025\/02\/image-5.png","article:published_time":"2025-07-18T17:52:49+00:00","article:modified_time":"2025-09-04T01:03:39+00:00","twitter:card":"summary_large_image","twitter:title":"CVE-2025-7528: Critical Buffer Overflow Vulnerability in Tenda FH1202 1.2.0.14(408) - Ameeba Blog","twitter:description":"Overview The cybersecurity landscape is constantly evolving with new vulnerabilities being discovered daily. One such critical vulnerability has been found in the Tenda FH1202 1.2.0.14(408) router model, specifically within the \/goform\/GstDhcpSetSer file. This vulnerability is considered critical due to its potential for remote code execution, which could lead to system compromise or data leakage. The","twitter:image":"https:\/\/www.ameeba.com\/blog\/wp-content\/uploads\/2025\/02\/image-5.png"},"aioseo_meta_data":{"post_id":"59473","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"limit_modified_date":false,"created":"2025-07-18 22:55:09","updated":"2026-05-28 21:15:55","focus_keyword":null,"additional_keywords":null,"truseo_locale":null,"ai":null,"breadcrumb_settings":null,"seo_analyzer_scan_date":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/www.ameeba.com\/blog\/\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/www.ameeba.com\/blog\/category\/uncategorized\/\" title=\"Uncategorized\">Uncategorized<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<strong>CVE-2025-7528: Critical Buffer Overflow Vulnerability in Tenda FH1202 1.2.0.14(408)<\/strong>\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/www.ameeba.com\/blog\/"},{"label":"Uncategorized","link":"https:\/\/www.ameeba.com\/blog\/category\/uncategorized\/"},{"label":"<strong>CVE-2025-7528: Critical Buffer Overflow Vulnerability in Tenda FH1202 1.2.0.14(408)<\/strong>","link":"https:\/\/www.ameeba.com\/blog\/cve-2025-7528-critical-buffer-overflow-vulnerability-in-tenda-fh1202-1-2-0-14-408\/"}],"_links":{"self":[{"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/posts\/59473","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/comments?post=59473"}],"version-history":[{"count":0,"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/posts\/59473\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/media?parent=59473"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/categories?post=59473"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/tags?post=59473"},{"taxonomy":"vendor","embeddable":true,"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/vendor?post=59473"},{"taxonomy":"product","embeddable":true,"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/product?post=59473"},{"taxonomy":"attack_vector","embeddable":true,"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/attack_vector?post=59473"},{"taxonomy":"asset_type","embeddable":true,"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/asset_type?post=59473"},{"taxonomy":"severity","embeddable":true,"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/severity?post=59473"},{"taxonomy":"exploit_status","embeddable":true,"href":"https:\/\/www.ameeba.com\/blog\/wp-json\/wp\/v2\/exploit_status?post=59473"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}